Unit won’t start
Red LED light flashing
at 7 second intervals
Unit won’t stay running
Low or No Catch
1. Propane tank may be empty.
2. If propane tank is new and has been newly filled
it must be purged.
3. There could be a loose connection.
4. Fuel line may be blocked by propane contaminants.
5. Bug Bag may be full or clogged.
1. ‘Possible Causes’ 1 & 3 above may apply.
2. Fuel line may be blocked by propane contaminants.
3. Regulator is not fully engaged.
1. Insects may not be out yet.
2. Trap placement issue.
3. Biting insect reproductive cycles have not yet
been broken.
4. Counterflow may be disrupted.
1. Weigh tank and check against “empty” weight written
on tank.
2. Bring tank to filling location. Air may be in fuel line. Ask
for tank to be purged.
Hint: If you have another propane
powered device operating on a standard 20 lb (9.07 kg)
propane tank, try hooking that tank up to the trap to
verify that the issue is with your tank.
3. Verify all connections. Make sure propane tank valve is
fully open.
4. See Quick Clear adapter instructions on page 10.
5. Replace the Bug Bag
6. Change all the batteries (min 5,4 V).
1. Go through above steps 1 & 3.
2. See Quick Clear adapter instructions on page 10.
3. See Tank Changing Tips on page 7.
1. Verify temperature is consistently over 50°F (10°C).
2. Follow steps in the “Trap Placement” section
of your owner’s manual or refer to your instructional
CD-ROM included with your trap.
3. Keep trap in constant operation 24 hours/day,
7 days per week for at least 4 weeks to reduce
the mosquito population.
4. Air flow may be restricted. Contact your Local
Service Provider.
LED Flashing alt RED/GREEN
at 7 second intervals
LED Flashing alt
RED/ORANGE
at 7 second intervals
High Temperature
Battery Voltage Low
1. Turn off trap and allow to cool for 1/2 hour.
Then restart.
1. Make sure the 4 “C” batteries are properly
installed and fresh.
2. Ensure the battery cage connector is properly
installed.
3. After several repeated unsuccessful
attempts, replace with 4 new “C” batteries.
Double flashing Red LED
at 7 second intervals
Thermister fault
1. Change to new 4C batteries and start the
machine again.
2. Contact your Local Service Provider.
1. Contact your Local Service Provider.
LED light solid red
Electrical fault
SolutionsPossible CauseProblem
Troubleshooting
1440-632_Indep_Scan_2011B 12/14/11 11:41 AM Page 13